Analyzers

Micro DPD Colorometric Chlorine Residual Analyzer

The MicroDPD analyzer uses proven DPD colorimetric technology for monitoring chlorine in both municipal and industrial applications. The instrument may also be used for controlling a pump or a valve via user selectable alarms or when used in conjunction with a 1450 or 1450 controller to provide residual control. It meets EPA guidelines for direct reporting to state agencies.


MicroChem II Probe Type Chlorine Residual Analyzer

Specifically designed for drinking and wastewater treatment plants and swimming pool applications, the MicroChem®II is able to measure up to three of the following parameters: pH, ORP, Dissolved Oxygen, Chlorine, Chlorine Dioxide, Bromine, Ozone, Conductivity, 4-20 mA, and Temperature (PT100).


Rosemount Chlorine Analyzer

Rosemount Free Chlorine Analyzer, complete system includes sensor, connecting cable, analyzer, and flow controller, sensor response is practically independent of pH between pH 6.5 and 10, no reagents, no auxiliary pH electrode, variopol quick-disconnect fittings makes sensor

replacement easy.


1870E Amperometric Chlorine Residual Ananlyzer

A reliable analyzer for continuous, accurate residual analysis. The amperometric-based instrument is designed to continuously analyze free or total chlorine, chlorine dioxide, iodine, bromine or other oxidants for water, wastewater, cooling water and other process water applications. The analyzers incorporate a constant, direct-drive electrode cleaning system which eliminates signal drift and the need for frequent recalibration. Internal high and low set points are standard.


Rosemount RDO O2 Analyzer

The RDO® sensor and analyzer is intended for the determination of dissolved oxygen in water. It is ideal for use in wastewater aeration basins and ponds. The sensor uses the fluorescence quenching method and unlike polarographic oxygen sensors, the RDO sensor does not require a flowing sample. It is also less affected by fouling than polarographic sensors. The RDO sensor is available with either integral or quick-disconnect cable. The maximum cable length is 4000 ft, a 1-¼ in FNPT fitting at the rear of the sensor allows a threaded pipe to be screwed into the sensor so it can be submerged in tanks or basins. Reliable, accurate readings and easy calibration procedure.


Rosemount Advanced Model 56 Dual Input Analyzer

The Rosemount Model 56 advanced analyzer supports continuous measurement of analytical inputs from one or two sensors. The modular design allows signal input boards to be field replaced, making configuration changes easy. The high resolution full-color display gives unsurpassed visibility and functionality for analytical instrumentation. Includes: datalogging, PID control and will interface with the following sensors: pH, ORP, Resistivity/ Conductivity, % Concentration, Total Dissolved Solids, Total Chlorine, Free Chlorine, Monochloramine, Oxygen, Ozone, Turbidity, Pulse Flow, ISE including Fluoride and Ammonium, Temperature, and others via 4-20mA input from any device.


ES2 Model LLD 1020 Liquid Leak Detector

ES2 developed the LLD-1020 for use in wastewater treatment facilities to monitor for liquid leaks on floors and secondary containment areas. With a NEMA 4X rating and a durable, reliable sensor this detector will give you an alarm when you need it. Available with cellular transmitter and solar powered. Made in the USA


Hach Pocket Colorimeter - Chlorine

The Hach Pocket Colorimeter™ II Filter Photometer is a true go-anywhere instrument. It’s lightweight and battery operated, suitable for extended field work or quick, on-the-spot process monitoring. The instrument has two channels in which measurements can be made. Belt holster is optional.


Clarity II Turbidimeter

Ideal for monitoring the turbidity of filtered drinking water. The Clarity II T56 from Rosemont Analytical is designed for the determination of turbidity levels in drinking water. It is also ideal for most raw waters, wastewater discharges, condensate returns and clarifiers. A display resolution of 0.001 and accuracy of ±2% of the reading is the result of the efficient bubble rejection design, low stray light and high instrument stability. Instruments with either a USEPA 180.1 compliant sensor using a visible light source or a ISO 702 compliant sensor using a near infrared LED are available. The turbidimeters meet either US or International regulatory standards.


SC400 Hand Held Chlorine Residual Tester

The Colorimeter SC400 is a rugged, waterproof, single parameter colorimeter for laboratory and field testing. The SC400 is available in four parameters: Chlorine (free and total), Chlorine Dioxide, Ammonia and Fluoride. This portable instrument uses the popular Powder Pack reagent chemistries and can be taken wherever residual values are monitored. The colorimeter features a large backlit display, a real-time clock, datalogging features and a user calibration mode which allows the user to calibrate against prepared standards.